- Arts & Culture 5939
- Business & Economics 689
- Computers 319
- Dictionaries & Encyclopedias 81
- Education & Science 75882
- Abstracts 252
- Astrology 4
- Astronomy 1
- Biology 8
- Chemistry 2221
- Coursework 15546
- Culture 9
- Diplomas 411
- Drawings 574
- Ecology 6
- Economy 83
- English 75
- Ethics, Aesthetics 3
- For Education Students 17613
- Foreign Languages 11
- Geography 3
- Geology 1
- History 89
- Maps & Atlases 5
- Mathematics 13856
- Musical Literature 2
- Pedagogics 19
- Philosophy 23
- Physics 14857
- Political Science 5
- Practical Work 101
- Psychology 60
- Religion 4
- Russian and culture of speech 8
- School Textbooks 7
- Sexology 42
- Sociology 9
- Summaries, Cribs 87
- Test Answers 150
- Tests 9243
- Textbooks for Colleges and Universities 32
- Theses 24
- To Help Graduate Students 14
- To Help the Entrant 37
- Vetting 364
- Works 13
- Информатика 10
- Engineering 3063
- Fiction 696
- House, Family & Entertainment 107
- Law 132
- Website Promotion 71
Design of the power supply system
Uploaded: 17.05.2019
Content: text 32 symbols
Product description
Introduction
Initial data
1. Selection and calculation of elements of SES.
1.1 Selection of wires of their brand, section for lines L3.
1.2 Selection of fuses and fuses
1.3 Selection of magnetic starters and thermal relay settings.
1.4 Determination of the estimated load JV.
1.5 Selection of cable brand and its section for line L2, circuit breaker and set point of its releases.
1.6 Selecting the brand of cable and its section for the line L1.
1.7 Calculation of single-phase short-circuit currents and the evaluation of the sensitivity of protection.
2. Assessment of voltage deviations in NVRS at Utsp = Uts.ps. = const.
2.2. Estimation of the limiting (maximum) values of voltage deviations on tires 0,4kV TP with confidence
probability of 0.95.
2.1 Calculation of the integral characteristics of the voltage deviation on the buses RU 0.4 kV TP. Choosing the best desoldering
PBV transformer TP.
2.3 Calculation of the voltage deviation in the maximum mode for blood pressure.
3. Assessment of voltage deviations in NVRS when counter voltage regulation in the TS.P.
3.1 Setting a specific value of the variance of the voltage deviations in the Ts.P., due to the counter
voltage regulation.
3.2 Calculation of the characteristics of voltage deviation, taking into account the counter regulation.
3.3 Calculation of the voltage deviation in the maximum mode for HELL taking into account the voltage regulation in the Ts.P.
4. Calculation of power losses.
4.1 Calculation of the maximum and average per day power loss in all elements of the design scheme.
4.2 Calculation of electricity losses per day in all elements of the system, an estimate in% of the magnitude of losses by
relation to the electricity transmitted for each network element. Estimate the percentage of losses in%
due to the uneven mode of power consumption.
4.3 Calculate the loss of power and electricity in the network elements due to the transfer of reactive
power and estimate in% the share of these losses in total losses.
Conclusion
References
Additional information
TEXT EXAMPLES:
Introduction
In this course work necessary to design the power supply system. To do this, select and calculate:
- SES elements (cables, wires, fuses and fuses, circuit breakers and magnetic starters, thermal relays)
- estimate the voltage deviation (without regulation in the Ts.P. and with counter regulation)
- loss of power and electricity
1.1 Selection of wires of their brand, section for lines L3.
For lines L3 choose wire brand AR with aluminum conductors and PVC insulation.
The choice of wire sections is carried out according to the heating condition:
Ip <Idl.
Ip - rated current of the wire, for the line L3.
1.2 Selection of fuses and fuses
Fuses should be installed in the power point to protect lines L3. The choice of a fusible insert is carried out according to the following conditions:
1.3 Selection of magnetic starters and thermal relay settings.
Magnetic actuators and thermal relays are designed to protect consumers from overload. We select magnetic starters according to the following condition:
To calculate the losses in the transformer, it is necessary to determine the type of transformer and its parameters. Technical data of transformers are given in table 2.106 p. 215 [3]
The TM-1000/10 transformer is designed with a voltage regulation device with the load removed (PBB). Table 12 shows the taps steps and the corresponding ET supplements.
Note: Course work in the format: DOCX - Microsoft Office Word - 24 pages of text